Click Here for An Immediate Factory Pricing Quote For the VTO-5750H-G ▶
Pricing Is Now On Display
Specifications
Model: VTO-5750H-G (1)
Heater (2)
kW : 27
Process Pump
HP : 7-1/2
GPM : 100
PSI : 44
Fluid Volume (6)
Unit : 5 gal
Expansion Tank : 5 gal
Maximum : 33 gal
Full Load Amperage (3)
230/3/60 : 90.8
460/3/60 : 5.8
575/3/60 : 36.6
Connection Sizes
To Process : 2"
From Process : 2"
Water Supply : 1/2"
Drain : 1/2"
Dimensions
Height : 65"
Width : 22"
Depth : 33"
Weight (5)
Shipping : 735 lbs
Specification Notes:
Since product innovation and improvement is our constant goal, all features and specifications are subject to change without notice or liability. Selection of certain optional features may change listed specifications.
Derate heater output by 25% for 208/3/60 operation.
Full load amps are higher than run load amps and must be used for sizing disconnects and supply wiring. Not for construction. Consult factory for power requirements of unit as configured and on selected options.
Consult factory for 50HZ operation.
Unit weight crated for shipment.
Maximum Total System @ 15% expansion = unit volume plus piping and prodcess volumes. Typical fluid expansion rates: a. Paratherm OR : 4.00% per 100°F b. Paratherm NF : 3.04% per 100°F c. Multitherm PG-1 : 3.10% per 100°F d. Calflo FG : 5.62? per 100°F
Do not use Multitherm 603.
Features
Tank Construction
Twin Tanks - separate heating and suction tanks
Large capacity expansion tank
NPT process connections
Process line shut-off valves
Tanks are flanged mounted to pump casing
Oil level sight glass
Air operated mold purge circuit
Fluid drain valve
Fluid fill port
Leak proof weldments
Process Pump
Low pressure centrifugal pump
Cast iron casing
Bronze pump impeller
Water cooled pump seal
Stainless steel pump motor
Air-Cooled Pump Seal
Heater
Flanged bolt-in mount
Vertical orientation
Steel heater sheath
Mercury heater contactor
Cabinetry
Stainless steel cabinetry with lift-off cover panel
Hinged electrical cabinet door
Portable, on casters
Galvanized steel base
Limits
Water supply pressure switch
Motor overload relay
Pressure relief valve (water)
High temperature limit
Options
Heat Exchanger
Larger heat exchanger sizes
System Alarms
Audible Alarm
Visual / audible beacon
Control Instruments
T500 Series Control
Cabinetry
Rear cover panel
Special Paint
Electrical
Nema 12 construction
Special electrics
Control Instrument
G500 Series
Easy to use menu driven controller
LCD display
Home screen includes continuous set point and to process temperature.
% Heating or Cooling indication on home screen.
Out-of-spec alarm including standard audible signal.
Oil temperature control units circulate oil through the process and are used for applications were the required temperature ranges from 100° to 500°F.
These units use a high flow pump to circulate high temperature oil through the process. A heater elevates the temperature of the oil. Cooling is provided through the use of an optional heat exchanger.
Units are available with a variety of control instruments, heaters sizes, cooling heat exchanger sizes, and physical packages.
This is a 'heating only' unit.
The centrifugal pump has a water-cooled pump seal for extended seal life.
VTO-5750H-G shown.
Image shown is typical. Actual unit appearance will vary according specifications and options.
Product innovation and improvement is our constant goal. All features and specifications are subject to change without notice or liability.
Products are assembled in the United States of America.