Temperature Control Unit | Oil Circulating | Heating Only
VTO-5750H-G
Click Here for An Immediate Factory Pricing Quote For the VTO-5750H-G ▶
Pricing Is Now On Display
Product Overview
The Hot Oil temperature control units are designed to control the temperature of your process by circulating a high temperature heat transfer fluid through the process.
This temperature control unit can be used in a wide range of industrial processes including; plastics, rubber, die casting as well as many other manufacturing processes that require a process fluid temperature range between 100˚F - 500°F.
A high flow pump circulates the fluid at the appropriate temperature to maintain a precise fluid and process temperature.
Depending on whether the process needs to be heated or cooled the circulated fluid is either heated by the electric heater or cooled indirectly via the available water
to oil heat exchanger.
These units are designed with the highest quality components and can be customized to meet your specific requirements.
Price is Loading
Specifications
Model: VTO-5750H-G (1)
Heater(2)
kW : 27
Process Pump
HP : 7.5
GPM : 100
PSI : 44
Fluid Volume(3)
Unit : 5 gal
Expansion : 5 gal
Maximum : 33 gal
Full Load Amperage(5)
230/3/60 : 90.8
460/3/60 : 45.8
575/3/60 : 36.6
Control Instrument
Type : G500 Series
Temperature Range : 100°F - 500°F
Connection Sizes
To Process : 2"
From Process : 2"
Water Supply : 1/2"
Drain : 1/2"
Dimensions
Height : 76"
Width : 27"
Depth : 45"
Weight(7)
Shipping : 735 lbs
Specification Notes:
Since product innovation and improvement is our constant goal, all features and specifications are subject to change without notice or liability. Selection of certain optional features may change listed specifications.
Derate heater output by 25% for 208/3/60 operation.
Maximum Total System @ 15% expansion = unit volume plus piping and prodcess volumes. Typical fluid expansion rates:
a. Paratherm OR : 4.00% per 100°F
b. Paratherm NF : 3.04% per 100°F
c. Multitherm PG-1 : 3.10% per 100°F
d. Calflo FG : 5.62 per 100°F
Do not use Mobiltherm 603.
Full load amps are higher than run load amps and must be used for sizing disconnects and supply wiring. Not for construction. Consult factory for power requirements of unit as configured and on selected options.
Low pressure, high flow centrifugal pump
eliminates high pressure safety concerns
Custom designed pump casings produce higher
flow with less horsepower
Water cooled pump seal maintains seal integrity
and lengthens service life
Seal cooling is provided by facility water
circulated within a cast jacket surrounding
the seal area
Process Connections
Female NPT fittings standard on all process connections
To and From Process connections supplied with shut off valves
Supplied with manual process fluid purge system allowing purging of the process for storage within the unit expansion tank. Requires low pressure compressed air source for operation.
Cabinetry & Frame
Stainless steel enclosure panels
Hinged electrical panel
Portable, on casters
Options
Control Instrument
Modbus TCP/IP RJ45
T500 control instrument
MRC-2 remote located control system for 2 temperature control units.
MRC-3 remote located control system for 1 temperature control unit
MRC-3 remote located control system with alarm and alarm silence switch
Cooling Circuit
Larger heat exchangers available for added capacity
Alarms
Audible Alarm
Beacon Alarm
Frame Construction
Rear cover panel
Control Instrument
G500 Series
Easy to use menu driven controller
LCD display
Home screen includes continuous set point and to process temperature.
% Heating or Cooling indication on home screen.
Out-of-spec alarm including standard audible signal.